Product Features
- Fully Automatic Inspection of Digital Soft Bag Batteries
- Automatic Load/Unload for Inspection and Sorting of Defects
- Real-Time Monitoring
- Conformation to Safety Radiation Standards
- Image Processing, Storage and Analysis
Fully Automatic Inspection:
- Connect upstream and downstream equipment
- Conduct inline automatic inspection and judgment
- Automatically sort out defective products
- Equipped with in-situ retesting function, optional with automatic reflux
retesting function.
Functions:
- Automatic Code Scanning, MES Interaction and Data Upload
- IV. OCV, Thickness, Size, And Corner Position
- Overhang Inspection (Positive And Negative Pole Range)
Specifications
Beat | ≥30 PPM (2 or 4 Corners) |
Excellence Rate | ≥99.5% |
Equipment Failure Rate | ≤2% |
Overkill Rate | ≤1% |
Missed Kill Rate | ≤0% |
Voltage Testing Accuracy | ±(0.0035﹪rdg. + 0.0005﹪fs) |
Internal Resistance Testing Accuracy | ±(0.5﹪rdg. + 0.10mΩ) |
Thickness Measurement Accuracy | ± 0.02mm |
Incoming Material Method | Tray Pallets, Loading/Unloading |
Radiation Safety Standards | ≤1uSV/hr |
Detector | Flat Panel Detector |
Photo Time | ≥0.7 Seconds |
Dimensions | 8500 L x 3200 W x 2800 H mm |
X-Ray Tube Specification | |
Voltage Range | 40 - 90 KV / 40 - 130 KV |
Current Range | 10 - 200 uA / 10 - 300 uA |
Inspection and Accuracy | |
Inspection Accuracy | 15 um |
Repetitive Testing Accuracy | ±30 um |
Others | |
Type Change Time | The replacement time for old varieties is ≤ 2hours/ per person; The replacement time for new varieties is ≤ 4 hours/ per person. |
Compatible Ranges | Mini Length: 40 - 160 mm Width: 35 - 120 mm Thickness: 5 - 15 mm Normal Length:40 - 160 mm Width:35 - 120 mm Thickness: 5 - 15 mm (or customized) |
Inspection Content | IV, OCV, Thickness, Size, Angle Position Overhang (Positive And Negative Pole Range) |